9999 THERMO KING GENERATOR Recall
- Campaign:
- 91E030000 on 08/18/1991
- Component:
- Equipment:electrical
- Manufactured:
- 12/31/1986 - 12/31/1990
- Affected:
- 463
- Defect:
- The material used in the pawl and shaft of the two top locking mechanisms in container clip-on diesel sets does not have adequate tensile strength or was not properly heat treated, and could cause the pawl and shaft to fracture.
- Consequence:
- Fracture of shaft while generator is in use may causeflying debris and result in injury to anyone in vicinity.
- Correction:
- Replace the cast iron shafts with forged steel shafts.
- Notes:
- System: generator.equipment description: 15 kw diesel generator; models; m9, m9a, m9b, m10, m10a,m19, m19a and m19b used in transport tailers to power refrigeration units.