9999 CUMMINS HGJAB TSBs (5)

Bulletin:
CPGF-S-00000421-
Component:
112000 electrical system:alternator/generator/regulator
Summary:
This product support bulletin was issued to alert the field that on certain generator sets there is an increase in nuisance fault code 36 (fc36) shutdowns, which many associate to overheat shutdowns. an overheat shutdown will usually first
Bulletin:
CPGF-S-00000436-
Component:
070000 fuel system, gasoline
Summary:
This product support bulletin was issued to alert the field of a stumbling and/or dying condition in rv and commercial mobile generator product lines caused by restrictions in the fuel lines from the fuel tank to the generator.
Bulletin:
TSB170121-112720
Component:
060000 engine and engine cooling
Summary:
This technical servcie bulletin describes the verification and resolution of the generator set will crank but not start and typically there will be no fault code but if the generator is cranked for too long (30 seconds), it will show fault
Bulletin:
TSB180048-041920
Component:
110000 electrical system
Summary:
This technical service bulletin describes the verification and resolution a potential wiring issue where the ignition coil and low engine oil level sensor leads were wired together instead of being wired to the correct leads on the control
Bulletin:
TSB180078-062020
Component:
060000 engine and engine cooling
Summary:
This technical service bulletin describes the verification and resolution of fault code 36 shutdowns on generators due to hot air recirculation. in certain situations, hot air coming from the ventilation exhaust can be recirculated into th

Home | Privacy