9999 SCI FUEL TANK Recall

Campaign:
95E025002 on 04/17/1996
Component:
Fuel system, other:storage:tank assembly:pressure relief devices
Manufactured:
05/31/1992 - 06/30/1994
Affected:
93
Defect:
Some temperature sensitive triggers were not x-rayed. these triggers could contain internal voids that would make the triggers susceptible to advanced creep causing false activation and venting of the cng.
Consequence:
Venting of the cng could result in a fire.
Correction:
Sci will replace the type iii prd with a suitable replace- ment device.
Notes:
System: fuel; cng; pressure relief valves/devices.equipment description: cng vehicle fuel tanks which incorporate the miradatype iii pressure relief device (prd).(see mirada campaign no. 95e025).note: if the valves have not been replaced within a reasonable time free ofcharge, please contact sci at 1-909-594-7777. also contact the national highwaytraffic safety administration's auto safety hotline at 1-800-424-9393.

9999 SCI FUEL TANK TSB

Bulletin:
BC0717961021
Component:
162000 structure:body
Summary:
Information for when replacing an interior trim component under warranty. *tt

Home | Privacy