9999 QUANTUM TECHNOLOGIES CNG FUEL TANK TSBs (23)
- Bulletin:
- TSB-020
- Component:
- 071100 fuel system, gasoline:storage:tank assembly
- Summary:
- Prd manifold mount. all generation 1 & 2 frame mount fsms hae pressure relief device (prd) manifolds. the prd manifolds are connected to a live port on the tank valve and are designed to safely vent the cylinder under certain conditions.
- Bulletin:
- TSB-019
- Component:
- 091000 fuel system, other:storage
- Summary:
- Itt regulator replacement. some quanturm fuel storage modules (fsm)s are built and supplied with itt pressure regulators as part of the fuel storage model. in some cases, the hgh pressure regulator (hpr) may experience gas leakage which
- Bulletin:
- TSB-018
- Component:
- 060000 engine (pws)
- Summary:
- Itt regulator erratic pressure regulation. some quantum fuel storage modules (fsms) are built and supplied with itt pressure regulators as part of the fuel storage module. in some cases, the high pressure regulator (hpr) may not respond
- Bulletin:
- TSB-015
- Component:
- 091000 fuel system, other:storage
- Summary:
- Cylinder movement in brackets. quantum fuel storage modules (fsms) are designedprove a safe and durable fuel storage solution for class 7 and class 8 commercial trucks. in some cases, the cylinder(s) may rotate and/or move laterally wit
- Bulletin:
- TSB-013
- Component:
- 060000 engine (pws)
- Summary:
- Engine backfire and related driveability issues when a vehicle is identified with a backfire it is recommended that the checks be followed in the indicated order. perform a diagnostic circuit check on the vehicle. verify that the mil
- Bulletin:
- TSB-016
- Component:
- 060000 engine (pws)
- Summary:
- High pressure regulator quantum fuel storage modules (fsms) are designed to provide a safe and durable fuel storage solution for class 7 and class 8 commercial trucks. in some cases, vehicles equipped with cummins engines may experience
- Bulletin:
- TSB-012
- Component:
- 081100 fuel system, diesel:storage:tank assembly
- Summary:
- Frame mount cylinder isolator replacement. cylinder isolators are used within a fuel storage module (fsm) to secure the cylinder to the vehicle. the isolators secure the cylinder to the brackets. as part of a periodic maintenance sched
- Bulletin:
- SI-003
- Component:
- 071000 fuel system, gasoline:storage
- Summary:
- All fuel storage modules (fsms) must be isolated from direct and indirect heat sources. the insulation kit provides extra protection against heat concerns when applied to a heat shield. in some cases, the installed location of the fsm may
- Bulletin:
- SI-004
- Component:
- 071000 fuel system, gasoline:storage
- Summary:
- Quantum fuel storage moduels (fsms) are designed to provide asafe and durable fuel storage solution for class 7 and class 8 commercial trucks. in some cases, the cylinder(s) may rotate and/or move laterally with the fuel storage module cyl
- Bulletin:
- TSB-011
- Component:
- 091000 fuel system, other:storage
- Summary:
- The itt regulator has an integrated prd which is designed to protect components downstream of the regulator. an integrated solenoid is used to control the fuel flow through the regulator. the regulator uses engine coolant to heat the regu
- Bulletin:
- CYL-TSB-004
- Component:
- 071000 fuel system, gasoline:storage
- Summary:
- Cylinder bracket and strap installation a number of cylinder bracket assemblies are available from various manufacturers that can be used to secure the quantum type 4 gaseous fuel cylinders to a vehicle. these bracket assemblies must be
- Bulletin:
- CYL-TSB-005
- Component:
- 071000 fuel system, gasoline:storage
- Summary:
- Cng cylinder valve adaptor all quantum type 4 cylinders use a valve adapter fitting that threads directly into the cylinder boss. this valve adapter fitting is locked in place and is not expected to move for the life of the cylinder.
- Bulletin:
- TSB-003
- Component:
- 023100 suspension:multiple axle:torque arm
- Summary:
- Cylinder bracket installation and strap torque a number of cylinder bracket assemblies are available from various manufacturers that can be used to secure the quantum tye 4 gaseous fuel cylinders to a vehicle. these bracket assemblies m
- Bulletin:
- TSB-006
- Component:
- 081100 fuel system, diesel:storage:tank assembly
- Summary:
- Prd manifold mount all fsms that utilize 80" and 90" cylinders have pressure relief device (prd) manifolds. the prd manifolds are connected to a live port on the tank valve and are designed to safely vent the cylinder under certain cond
- Bulletin:
- CYL-TSB-007
- Component:
- 071000 fuel system, gasoline:storage
- Summary:
- Integrated isolator over wrap separation some cylinders have been constructed with the isolator integrated directly with the cylinder. the isolator is made of rubber and is fixed to the cylinder using wings that extend from the sides of
- Bulletin:
- TSB-008
- Component:
- 091120 fuel system, other:storage:tank assembly:mounting
- Summary:
- Frame mount end caps the end caps provide support for the steps and covers for frame mounted fuel storage modules. in some cases, the operational environment for the frame mounted fsms may cause the end caps built before mid july 2014
- Bulletin:
- TSB-009
- Component:
- 111000 electrical system:battery
- Summary:
- High voltage safety disconnect when hybrid escapes are converted to plug-in hybrid electric vehicle (phev) escapes, the factory high voltagebattery is replaced with quantum components. as a result, the high voltage safety disconnect (hv
- Bulletin:
- TSB-010
- Component:
- 350000 equipment
- Summary:
- Omb automatic valve plunger failure omb lyra automatic valves use a plunger and core assembly to control the flow of cng through the valve. the plunger and core are internal within the automatic valve. when these valves fail, customers m
- Bulletin:
- TSB-002
- Component:
- 354000 equipment:mechanical
- Summary:
- Cylinder bracket installation and strap torque a number of cylinder bracket assemblies are available from various manufacturers that can be used to secure the quantum type 4 gaseous fuel cylinders to a vehicle. these bracket assemblies mu
- Bulletin:
- TSB-001
- Component:
- 111000 electrical system:battery
- Summary:
- Diagnostic trouble codes when escape hybrids are converted to phev escape hybrids, the factory high voltage battery and battery control module (bcm) are replaced with quantum components. this system operates differently than the ford syst
- Bulletin:
- TSB 032
- Component:
- 350000 equipment
- Summary:
- Over time the collar bushing may loosen which can result in increased noise from the trailer and or loss of the lower collar bushing. a retainer is being installed to prevent loss of the bushing.
- Bulletin:
- TSB 031
- Component:
- 161000 structure:frame and members
- Summary:
- Accelerated wear and corrosion at the interface between the container front sill and the chassis rail have been observed. this accelerated wear can result in weakening of the front of the container and a settling of the container on the cha
- Bulletin:
- TSB-034
- Component:
- 100000 power train
- Summary:
- The finish on the cross members used in some of the quantum vp trailers can have an effect on the ability of the upper cylinder support collar fasteners to retain torque. the finish can creep from under the head of the bolt over time, which
Home | Privacy