9999 MAGNETEK POWER CONVERTER Recall
- Campaign:
- 95E016000 on 05/18/1995
- Component:
- Electrical system:fuses and circuit breakers
- Manufactured:
- 12/31/1993 - 12/31/1994
- Affected:
- 125,350
- Defect:
- A solder bridge on the printed circuit board passed undetected through a test fixture and bypasses the fuse protecting the circuit.
- Consequence:
- This solder bridge, when coupled with a dead short else where in the system, can result in circuit overload, overheating, and even fire, without warning.
- Correction:
- Detailed test instructions are being provided to magnetek dealers. if a defective fuse panel is found, a new replacement panel will be installed.
- Notes:
- System: electrical; fuse and fuse recepticle. equipment description: fuse panels used in power converters for recreationalvehicles and supplied to magnetek, inc.note: if the fuse panels are not replaced free of charge within a reasonable time, please contact doran at 1-800-681-5424. also contact the national highway traffic safety administration's auto safety hotline at 1-800-424-9393.