9999 DYNASYS APU Recall

Campaign:
13E006000 on 02/05/2013
Component:
Electrical system
Affected:
3,274
Defect:
Hodyon, inc. is recalling certain dynasys auxillary power units (apu) distributed between october 2009 and december 2012. the wire that connects the apu to the heating, ventilation and cooling (hvac) unit may be under-rated for the electrical current. if the wire becomes bent or kinked, it may have reduced current carrying capacity resulting localized overheating.
Consequence:
If flammable materials are near the overheated wire, there is an increased risk of fire and personal injury.
Correction:
Hodyon has sent interim notification letters to the affected customers, and dealers will rewire the affected electrical components going to the hvac system. the recall began on february 19, 2013. owners may contact dynasys customer service at 1-800-289-8282 ext 3.
Notes:
Hodyon's recall campaign number is tsb-01242013.owners may also contact the national highway traffic safety administration vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to www.safercar.gov.

Home | Privacy