9999 DORAN 30506922 Recall

Campaign:
95E016000 on 05/18/1995
Component:
Electrical system:fuses and circuit breakers
Manufactured:
12/31/1993 - 12/31/1994
Affected:
125,350
Defect:
A solder bridge on the printed circuit board passed undetected through a test fixture and bypasses the fuse protecting the circuit.
Consequence:
This solder bridge, when coupled with a dead short else where in the system, can result in circuit overload, overheating, and even fire, without warning.
Correction:
Detailed test instructions are being provided to magnetek dealers. if a defective fuse panel is found, a new replacement panel will be installed.
Notes:
System: electrical; fuse and fuse recepticle. equipment description: fuse panels used in power converters for recreationalvehicles and supplied to magnetek, inc.note: if the fuse panels are not replaced free of charge within a reasonable time, please contact doran at 1-800-681-5424. also contact the national highway traffic safety administration's auto safety hotline at 1-800-424-9393.