2017 ARBOC SPIRIT OF MOBILITY TSBs (7)

Bulletin:
AR840
Component:
020000 suspension
Summary:
Complaint: desiccant dryer filters failing within months of installation which potentially leads to failure of pressure transducer and thomas compressor. cause-tanks need to be drained daily instead of previous instruction of every oil chan
Bulletin:
AR841
Component:
356000 equipment adaptive
Summary:
Complaint-dedicated micros box bracket cracking. cause-bracket 1309054 does not have enough material between slotted hole and exterior edge of part. correction- replace bracket 1309054 with revised bracket 1310546. affects only dallas dart
Bulletin:
AR842
Component:
020000 suspension
Summary:
Complaint: desiccant dryer filters failing within months of installation which potentially leads to failure of pressure transducer and thomas compressor. cause-tanks need to be drained daily instead of previous instruction of every oil chan
Bulletin:
AR845
Component:
110000 electrical system
Summary:
Ar845-replacing underhood 100a with 120a circuit breaker. complaint-100a circuit breaker tripping prematurely. cause-manufacturing tolerances of the breaker and the temperature derate curve associated with the breaker. correction-replace un
Bulletin:
AR847
Component:
110000 electrical system
Summary:
Ar847-loose thermo king power & ground lugs inspection-repair. complaint-power/ground lugs looseat connection points at circuit breaker or ground bar. cause-lugs incorrectly crimped or loose connections at circuit breaker or ground bar. cor
Bulletin:
AR860
Component:
161000 structure:frame and members
Summary:
Ar860-front pivot mount inspection and repair. complaint-pivot mount bolts having repeated premature failure. cause-spring pivot bolt movement allowed by elongated mounting hole. correction-inspect/replace bolt. labor allowance 2 hours per
Bulletin:
AR861
Component:
020000 suspension
Summary:
Ar861-upper shock/track bar mount inspection and repair. complaint-upper plates previously installed in ar839 are cracking and pulling away from frame. cause-insuffiecient/bad welds not holding under loads. correction-inspect/correct welds