2009 MEDTEC AMBULANCE Recalls (2)

Campaign:
09V108000 on 03/31/2009
Component:
Seat belts:front:anchorage
Manufactured:
12/06/2006 - 01/22/2009
Affected:
72
Defect:
Medtec is recalling 72 my 2007-2009 additional duty ambulances. the seat belt anchors for the squad bench are fastened to the sidewall of the ambulance body, using 1/4-20 self-threading machine screws. in some cases, incorrect mounting screws were installed. the seat belt anchors could pull free of the wall mounting.
Consequence:
If this were to happen, serious injury or death could occur.
Correction:
Dealers will inspect the seat belt anchors and make sure the anchor fasteners are tight and the fasteners are not missing or partially pulled out. the recall is expected to begin during may 2009. owners may contact medec at 1-866-263-3832.
Notes:
Owners may also contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to <a href=http://www.safercar.gov>http://www.safercar.gov</a> .

Campaign:
12V554000 on 12/03/2012
Component:
Seats
Manufactured:
01/01/2009 - 04/30/2011
Affected:
977
Defect:
Medtec is recalling certain model year 2009-2011 ambulances (type i, type i-ad, type ii, type iii, and type iii-ad) manufactured from january 2, 2009, through may 1, 2011. if an attendant lands on the bench top with great force, such as when the vehicle hits a bump in the road, the bench top screws may loosen and pull out.
Consequence:
If the bench top securing screws pull out then the bench top may drop into the cavity of the bench compartment, increasing the risk of personal injury.
Correction:
Medtec will notify owners, and dealers will repair the vehicles free of charge. the recall began on january 8, 2013. owners may contact medtec toll-free at 1-866-263-3832.
Notes:
Medtec's recall campaign number is 74b238m.owners may also contact the national highway traffic safety administration vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to www.safercar.gov.