2000 NEWMAR MOUNTAIN AIRE Recalls (7)

Campaign:
00V227000 on 08/29/2000
Component:
Equipment:other:labels
Manufactured:
11/09/1999 - 06/01/2000
Affected:
198
Defect:
Vehicle description: motor homes. incorrect information has been used on the vehicle identification number (vin) tag. the tag shows tires information located under cold inflation pressure as 131 psi for the front and 123 psi for the rear. the maximum tire inflation pressure for the rim is 120 psi. this does not comply with the requirements of fmvss 120, "tire selection and rims for motor vehicles other than passenger cars."
Consequence:
The rim could possibly fail, increasing the risk of a crash.
Correction:
New tags will be sent to owners.
Notes:
Owner notification is expected to begin during august 2000.owners who do not receive the free replacement label within a reasonable time should contact newmar at 1-800-731-8300.also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-dot (1-888-327-4236).

Campaign:
00V315000 on 10/25/2000
Component:
Fuel system, gasoline:delivery:hoses, lines/piping, and fittings
Manufactured:
12/31/1999 - 08/30/2000
Affected:
1,263
Defect:
Vehicle description: front and rear engine motor homes built on ford, spartan and workhorse chassis. all front engine class a motor homes built on ford and workhorse chassis were manufactured from january 1, through august 31, 2000. all rear engine motor homes built on spartan chassis were built from february 23 through august 31, 2000. these vehicles fail to comply with requirements of fmvss no. 301, "fuel system integrity." an incorrect vent hose was installed on the fill nozzle to the fuel tank. the hose can break down allowing fuel leakage.
Consequence:
Fuel leakage in the presence to an ignition source could result in a fire.
Correction:
Dealers will replace the fuel vent hose.
Notes:
Owner notification is expected to begin during october 2000.owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact newmar at 1-800-731-8300. also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-dot (1-888-327-4236).

Campaign:
03V064000 on 03/16/2003
Component:
Service brakes, hydraulic:switches:brake warning
Manufactured:
08/30/1999 - 09/25/2002
Affected:
1,227
Defect:
Certain motor home chassis fail to comply with the requirements of federal motor vehicle safety standard no. 105, "hydraulic and electric brake systems." the brake system warning indicator may not function as required by standard.
Consequence:
In some of the affected vehicles, the brake system warning indicator will not illuminate when the ignition is in the start position or for a low brake fluid condition, if the body builder relied solely upon ford's ivm compliance statement for the brake system warning indicator.
Correction:
Dealers will revise the brake warning lamp circuit. owner notification began april 14, 2003. owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact newmar at 1-574-773-7791.
Notes:
Customers can also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-dot (1-888-327-4236).

Campaign:
07V075000 on 03/04/2007
Component:
Equipment:recreational vehicle
Manufactured:
03/31/1997 - 05/30/2003
Affected:
16,190
Defect:
Certain class a and diesel pusher motor homes and fifth wheel trailers equipped with a two-door refrigerator, manufactured by the dometic corporation, may have a defect in the boiler tube. pressurized coolant solution could be released into an area where an ignition source (gas flame) is present.
Consequence:
Release of coolant under certain conditions could ignite and result in a fire.
Correction:
Newmar will be working with dometic in order to repair these refrigerators (please see 06e076). dometic will repair these refrigerators by installing a secondary burn housing, a thermal fuse, and a melt fuse free of charge. dometic has retained stericycle inc. to manage this campaign. stericycle will assist you in locating dealerships or service centers and will provide assistance with scheduling of appointments. owners may contact dometic/stericycle at 1-888-446-5157 or newmar at 1-574-773-7791.
Notes:
Customers may contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty: 1-800-424-9153); or go to http://www.safercar.gov.

Campaign:
08V025000 on 01/23/2008
Component:
Vehicle speed control
Affected:
5,575
Defect:
On certain class a motor homes constructed on ford f-53ty1 and p131 motor home chassis and equipped with speed control, the speed control deactivation switch may overheat.
Consequence:
Overheating could result in smoke or burn and an underhood fire.
Correction:
Newmar is working with ford in conducting this recall. ford will install a fused wiring harness into the speed control system free of charge. owners may contact ford at 1-866-436-7332 or newmar at 574-773-7791. (note: also see ford recalls 05v017, 05v388, and 06v286)
Notes:
Newmar recall no. 05s28.customers may also contact the national highway traffic safety administration's vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to http://www.safercar.gov.

Campaign:
15V829000 on 12/08/2015
Component:
Steering
Manufactured:
01/04/1997 - 05/25/2005
Affected:
1,920
Defect:
Newmar corporation (newmar) is recalling certain model year 1997-2005 dutch star and mountain aire, 1998-1999 london aire, 2004 essex and 1997-1998 kountry aire motorhomes. the affected vehicles have a steering gear mounting bracket that may crack, causing a loss of steering ability.
Consequence:
A loss of steering increases the risk of a crash.
Correction:
Newmar will notify owners, and spartan dealers will replace the steering gear mounting brackets, free of charge. the recall began on january 4, 2016. owners may contact newmar customer service at 1-800-731-8300 or spartan customer service at 1-800-543-4277. newmar's number for this recall is 15v 633.
Notes:
Owners may also contact the national highway traffic safety administration vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to www.safercar.gov.

Campaign:
17V809000 on 12/19/2017
Component:
Equipment
Manufactured:
07/23/1997 - 11/02/2017
Affected:
34,699
Defect:
Newmar corporation (newmar) is recalling various 1995-2018 motorhomes. a list of the affected vehicles available at: https://static.nhtsa.gov/odi/rcl/2017/rmisc-17v809-2309.pdf. these motorhomes are equipped with kidde plastic-handle or push button 'pindicator' fire extinguishers that may become clogged, preventing the extinguisher from discharging as expected or excessive force may be needed to activate the extinguisher. additionally, in certain models, the nozzle may detach from the valve assembly with enough force that it could cause injury and also render the product inoperable. for a full list of the affected fire extinguisher models visit: https://static.nhtsa.gov/odi/rcl/2017/rmisc-17e062-5427.pdf
Consequence:
In the event of a fire, if the fire extinguisher does not function properly, it can increase the risk of injury.
Correction:
Newmar will notify owners, and instruct them to contact kidde for a replacement fire extinguisher, free of charge. the recall began on february 7, 2018. owners may contact kidde customer service toll-free at 1-855-262-3540, or online at www.kidde.com and click on "product safety recall" for more information or owners may contact newmar customer service at 1-574-773-7791. newmar's number for this recall is 17e-062.
Notes:
Owners may also contact the national highway traffic safety administration vehicle safety hotline at 1-888-327-4236 (tty 1-800-424-9153), or go to www.safercar.gov.

2000 NEWMAR MOUNTAIN AIRE TSBs (2)

Bulletin:
TSB-372
Component:
150000 seat belts
Summary:
Newmar corp.: failed amsafe seat belts being returned to newmar for warranty coverage. please note that when changing out warranty amsafe seat belts, both harness strap with clip and buckle portion will need to be returned. all motorized
Bulletin:
PIB 494
Component:
350000 equipment
Summary:
If the coach's hwh leveling system has intermittent issues when operating, check for corrosion or loose mounting bolts. torque the mounting bolts (if needed) to 30 ft. pounds. a ground cable may also be installed to improve the overall grou