1994 TERRA MPV Recall

Campaign:
95E016004 on 04/17/1996
Component:
Electrical system:fuses and circuit breakers
Manufactured:
06/30/1994 - 06/30/1994
Affected:
1
Defect:
A solder bridge on the printed circuit board within the fuse panel of the power converter passed undetected through a test fixture and bypasses the fuse protecting the circuit.
Consequence:
This solder bridge, when coupled with a dead short else where in the system, can result in circuit overload, overheating, and even fire, without warning.
Correction:
Detailed test instructions are being provided. if a defective fuse panel is found, a new replacement panel will be installed.
Notes:
System: electrical; fuse and fuse recepticle. vehicle equipment: transit bus equipped with magnetek power converters which use a doran manufacturing fuse panel. (see doran campaign no. 95e016). note: if the fuse panels are not replaced free of charge within a reasonable time, please contact doran at 1-800-681-5424. also contact the national highway traffic safety administration's auto safety hotline at 1-800-424-9393.