1987 NEOPLAN NEOPLAN Recalls (2)

Campaign:
88V082000 on 05/23/1988
Component:
Fuel system, gasoline:storage:tank assembly:filler pipe and cap
Manufactured:
12/31/1976 - 12/31/1987
Affected:
28
Defect:
Fuel filler neck could be positioned or installed in a way that allows fuel to enter the passenger compartment under certain conditions.
Consequence:
Fuel odor would be present and in presence of an ignitionsource, could result in a fire.
Correction:
Remove fuel filler neck and relocate below floorline of bus.
Notes:
System: fuel filler neck.vehicle description: 40 ft. metroliner buses.

Campaign:
88V083000 on 05/23/1988
Component:
Electrical system:fuses and circuit breakers
Manufactured:
12/31/1976 - 12/31/1987
Affected:
758
Defect:
The 25 amp automatic reset circuit breaker could fail in the closed position.
Consequence:
This could jeopardize the circuitry to be protected bythe circuit breaker and could result in an electrical fire.
Correction:
Replace circuit breaker.
Notes:
System: electrical/circuit breaker.vehicle description: 30, 35, 40, and 60 ft. transit buses.